Frequency-domain endoscopic diffuse optical tomography reconstruction algorithm based on dual-modulation-frequency and dual-points source diffuse equation

机译:基于双调制频率和双点源扩散方程的频域内窥镜漫射光学层析成像重建算法

获取原文
获取原文并翻译 | 示例

摘要

In this paper, frequency-domain endoscopic diffuse optical tomography image reconstruction algorithm based on dual-modulation-frequency and dual-points source diffuse equation is investigated for the reconstruction of the optical parameters including the absorption and reducing scattering coefficients. The forward problem is solved by the finite element method based on the frequency domain diffuse equation (FD-DE) for dual-points source approximation and multi-modulation-frequency. In the image reconstruction, a multi-modulation-frequency Newton-Raphson algorithm is applied to obtain the solution. To further improve the image accuracy and quality, a method based on the region of interest (ROI) is applied on the above procedures. The simulation is performed in the tubular model to verily the validity of the algorithm. Results show that the FD-DE with dual-points source approximate is more accuracy at shorter source-detector separation. The reconstruction with dual-modulation-frequency improves the image accuracy and quality compared to the results with single-modulation-frequency and triple-modulation-freo,uency method. The peak optical coefficients in ROI (ROImax) are almost equivalent to the true optical coefficients with the relative error less than 6.67%. The full width at half maximum (FWHM) achieves 82% of the true radius. The contrast-to-noise ratio (CNR) and image coefficient(IC) is 5.678 and 26.962, respectively. Additionally, the results with the method based on ROI show that the ROImax is equivalent to the true value. The FWHM can improve by 88% of the true radius. The CNR and IC is improved over 7.782 and 45.335, respectively.
机译:本文研究了基于双调制频率和双点源扩散方程的频域内窥镜漫射光学层析成像图像重建算法,以重建包括吸收系数和降低散射系数的光学参数。通过基于频域扩散方程(FD-DE)的双点源近似和多调制频率的有限元方法解决了前向问题。在图像重建中,采用多调制频率牛顿-拉夫森算法获得解。为了进一步提高图像的准确性和质量,在上述过程中应用了基于关注区域(ROI)的方法。在管状模型中执行仿真以验证算法的有效性。结果表明,具有双点源近似值的FD-DE在较短的源-检测器间距下精度更高。与单调制频率和三调制频率的有效方法相比,双调制频率的重建提高了图像的准确性和质量。 ROI中的峰值光学系数(ROImax)几乎等于真实光学系数,相对误差小于6.67%。半高全宽(FWHM)达到真实半径的82%。对比噪声比(CNR)和图像系数(IC)分别为5.678和26.962。此外,基于ROI的方法的结果表明ROImax等于真实值。 FWHM可以提高真实半径的88%。 CNR和IC分别提高了7.782和45.335。

著录项

  • 来源
    《Optical tomography and spectroscopy of tissue X》|2013年|85782H.1-85782H.14|共14页
  • 会议地点 San Francisco CA(US)
  • 作者单位

    College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China;

    College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China;

    College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China ,Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, China;

    College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China;

    College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China;

    College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China ,Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, China;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Diffuse optical tomography; frequency-domain; endoscopic; the effective detection range; dual-points source approximation; dual-modulation-frequency;

    机译:漫射光学层析成像;频域内窥镜有效检测范围;双点源近似;双调制频率;