首页> 外文会议>Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE >Ultra high resolution SPECT with CdTe for small animal imaging applications: Monte Carlo simulation study using voxelized phantom
【24h】

Ultra high resolution SPECT with CdTe for small animal imaging applications: Monte Carlo simulation study using voxelized phantom

机译:带有CdTe的超高分辨率SPECT用于小型动物成像应用:使用体素化体模的Monte Carlo模拟研究

获取原文
获取外文期刊封面目录资料

摘要

The single photon emission computed tomography (SPECT) based on pixelated Cadmium Telluride (CdTe) detector has been promising for high resolution small animal imaging. For the feasibility of our ultra-high resolution SPECT system with CdTe, we compared the quality of the reconstructed image of our SPECT system to that of a conventional small animal SPECT system with NaI(Tl) detector. The pixel size of CdTe detector was 0.35 mm × 0.35 mm which was available for a real detector (PID350, AJAT, Finland). The detector size was 44.8 × 44.8 mm with 128 × 128 pixels and the thickness of this detector was 1 mm. The intrinsic resolution of CdTe detector and that of NaI(Tl) detector were 0.35 mm and 2.3 mm, respectively. The height parallel hole collimator made of lead was 25 mm and that of a septum was 0.2 mm. The shape of that parallel hole collimator and its radius were hexagonal and 0.5 mm, respectively. A SPECT liver scan was simulated for both SPECT with CdTe and conventional SPECT system using voxelized MOBY phantom. All SPECT images were obtained using 120 projection views acquired from 0° to 360° with a 3°. Slices were reconstructed using an Ordered Subsets Expectation Maximization (OS-EM) and 5 iterations with 4 subsets. We compared the quality of images for two systems in terms of spatial resolution (FWHM), sensitivity, signal-to-noise ratio (SNR), and contrast-to-noise (CNR). Our simulation results indicated that the reconstructed SPECT images obtained with CdTe detector showed higher resolution compared to those with the conventional scintillation detector. These results demonstrated that the SPECT imaging based on pixelated CdTe detector can improve the performance of SPECT system for small animal imaging.
机译:基于像素化碲化镉(CdTe)检测器的单光子发射计算机断层扫描(SPECT)已有望用于高分辨率小动物成像。为了使我们的超高分辨率SPECT系统具有CdTe的可行性,我们将SPECT系统的重建图像质量与带有NaI(Tl)检测器的常规小动物SPECT系统的图像质量进行了比较。 CdTe检测器的像素大小为0.35 mm×0.35 mm,可用于实际检测器(PID350,AJAT,芬兰)。检测器尺寸为44.8×44.8 mm(128×128像素),检测器的厚度为1 mm。 CdTe检测器和NaI(Tl)检测器的本征分辨率分别为0.35 mm和2.3 mm。由铅制成的高度平行孔准直仪为25 mm,隔垫的高度为0.2 mm。该平行孔准直器的形状及其半径分别为六边形和0.5 mm。使用体素化的MOBY体模对使用CdTe的SPECT和常规SPECT系统的SPECT肝脏扫描进行了模拟。使用从0°到360°以及3°的120个投影视图获得所有SPECT图像。使用有序子集期望最大化(OS-EM)以及5个具有4个子集的迭代来重建切片。我们在空间分辨率(FWHM),灵敏度,信噪比(SNR)和对比度噪声(CNR)方面比较了两个系统的图像质量。我们的仿真结果表明,与常规闪烁探测器相比,CdTe检测器获得的重建的SPECT图像显示出更高的分辨率。这些结果表明,基于像素化CdTe检测器的SPECT成像可以提高SPECT系统在小动物成像中的性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号