摘要

The Correlation Spectrum Analyzer, thanks to the presence of two independent acquisition channels, has demonstrated to reach very high performance in measuring noise spectra and to be extremely flexible in adapting to different devices under test (DUT) in term of impedance values, of flowing standing current, of DC applied voltage and of the physical quantity to be measured, either current or voltage. In addition, it can selectively extract the noise contribution of a specific current flow in multi-electrodes devices. The paper will briefly highlights these features together with the influence of the DUT characteristics, such as its impedance to ground and the cross-impedance between the two electrodes connected to the instrument input ports, in determining the ultimate limits in the performance of the instrument in terms of its sensitivity, its precision and its spectral extension. A practical realisation for measurements made with an AFM especially modified for correlation investigations is also commented.
机译:借助两个独立的采集通道,相关频谱分析仪已证明在测量噪声频谱方面具有非常高的性能,并且在阻抗值,流动平稳性方面非常灵活地适应不同的被测设备(DUT)电流,直流施加电压和要测量的物理量(电流或电压)。此外,它可以有选择地提取多电极设备中特定电流的噪声贡献。本文将简要介绍这些功能以及DUT特性的影响,例如DUT对地的阻抗以及连接到仪器输入端口的两个电极之间的交叉阻抗,以确定仪器在性能方面的最终极限。灵敏度,精度和光谱扩展方面。还评论了用原子力显微镜(AFM)进行的测量的实际实现,特别是针对相关性研究进行了修改。