首页> 外文会议>Nanoscale imaging, sensing, and actuation for biomedical applications X >Self-Referenced Silicon Nitride Array Microring Biosensor for Toxin Detection Using Glycans at Visible Wavelength
【24h】

Self-Referenced Silicon Nitride Array Microring Biosensor for Toxin Detection Using Glycans at Visible Wavelength

机译:自参考的氮化硅阵列微环生物传感器用于在可见波长下使用聚糖检测毒素。

获取原文
获取原文并翻译 | 示例

摘要

We report on application of on-chip referencing to improve the limit-of-detection (LOD) in compact silicon nitride (SiN) microring arrays. Microring resonators, fabricated by e-beam lithography and fluorine-based etching, are designed for visible wavelengths (656nm) and have a footprint of 20 × 20 μm. GM1 ganglioside is used as the specific ligand for recognition of Cholera Toxin Subunit B (CTB), with Ricinus Communis Agglutinin I (RCA I) as a negative control. Using micro-cantilever based printing less than 10 pL of glycan solution is consumed per microring. Real-time data on analyte binding is extracted from the shifts in resonance wavelengths of the microrings.
机译:我们报告了片上参考的应用,以改善紧凑型氮化硅(SiN)微环阵列中的检测限(LOD)。通过电子束光刻和氟基蚀刻制成的微环谐振器设计用于可见光波长(656nm),占地面积为20×20μm。 GM1神经节苷脂被用作识别霍乱毒素亚基B(CTB)的特异性配体,而蓖麻蓖麻凝集素I(RCA I)作为阴性对照。使用基于微悬臂梁的打印,每个微环消耗少于10 pL的聚糖溶液。从微环共振波长的变化中提取有关分析物结合的实时数据。