A stator fault of induction motor occurs due to the breakdown of insulation, meaning the stator is directly connected with the power supply, and the direct connection is a direct cause of a major accident. For this reason, many studies are being performed to detect the faults. As for the existing studies on stator fault detection, they are being performed considering the possibility of stator fault only, excluding the possibility of rotor fault. It is necessary to identify and detect whether a stator (or rotor) fault is the cause of the electrical fault. This paper suggested a new algorithm that identifies the causes of stator faults with the use of the change in the duty ratio of the half-period frequency of the frequency when a phase angle change occurs at that moment. Also, by applying the algorithm to the fault of the rotor, it was also possible to grasp their fault state and to identify accurately whether a stator (or rotor) fault is the cause of an electrical fault.
机译:由于绝缘击穿而发生感应电动机的定子故障,这意味着定子与电源直接连接,直接连接是主要事故的直接原因。因此,正在执行许多研究以检测故障。至于对定子故障检测的现有研究,他们正在考虑定子故障的可能性,不包括转子故障的可能性。有必要识别和检测定子(或转子)故障是否是电故障的原因。本文建议了一种新的算法,其识别定子故障的原因在当时发生相角变化时,使用频率的半周期频率的占空比的变化。此外,通过将算法应用于转子的故障,还可以掌握其故障状态并准确地识别定子(或转子)故障是否是电气故障的原因。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号