首页> 外文会议>Symposium on oxidative behavior of materials by thermal analytical techniques >A proposed reference material for oxidative induction time by differential scanning calorimatry
【24h】

A proposed reference material for oxidative induction time by differential scanning calorimatry

机译:通过差示扫描量热法进行氧化诱导时间的提出的参考材料

获取原文
获取外文期刊封面目录资料

摘要

A polyethylene film sample, inhibited with a hindered phenol antioxidant, is proposed as a Standard Reference Material for oxidative induction time (OIT) testing. The mean OIT values, derived from nine interlaboratory studies and for a number of experimental conditions, are presented. The material is found to be statistically homogeneous, a necessary condition for a reference material. Further, the effects of temperature, oxygen pressure, and storage time on the proposed reference material are explored. As a kinetic parameter, the OIT value appears to be decreasing with time but in a well behaved and predictable manner. The use of a table and graph permit the user of the material to estimate its OIT value in the future. Because the material has been thoroughly tested in a wide variety of OIT conditions, it appears to be the best currently availabile candidate and is offered for consideration as an OIT Reference Material.
机译:用受阻酚抗氧化剂抑制的聚乙烯薄膜样品被提出为氧化诱导时间(OIT)测试的标准参考材料。 提出了来自九项合作性研究和许多实验条件的平均oIt值。 发现该材料是统计上均匀的,参考材料的必要条件。 此外,探讨了温度,氧气压力和储存时间对所提出的参考材料的影响。 作为动力学参数,oIt值似乎随时间逐渐减小,但以良好的表现和可预测的方式。 使用表和图允许材料的用户在将来估计其OIT值。 由于材料在各种各样的oIt条件下进行了彻底测试,因此它似乎是最佳的当前可用的候选人,并提供作为OIT参考资料的考虑。