首页> 外文会议>International E-Conference on Industrial, Mechanical, Electrical and Chemical Engineering >Finite Element Analysis of Different Artificial Hip Stem Designs Based on Fenestration under Static Loading
【24h】

Finite Element Analysis of Different Artificial Hip Stem Designs Based on Fenestration under Static Loading

机译:基于静态荷载作用下不同人工髋关节设计的有限元分析

获取原文

摘要

Permanent hip joint damage caused by calcification, aging, or accidents requires replacement using artificial hip joint replacement surgery. Among the biomaterial applications, the Total Hip Replacement (THR) method is the most successful. Many types of artificial hip joints are available in the commercial market. Various types of material and design can be selected to suit the needs of the patients. One of which is the design with fenestration type on the hip stem. In terms of materials, Titanium and stainless steel are the ones commonly used in hip joint replacement. In this paper, the effects of fenestration hip stem on mechanical behavior have been studied using the finite element analysis. Several hip designs, i.e., the hip joint without fenestration, hip joint with fenestration slot, hip joint with fenestration big loop, and hip joint with fenestration multi-loop, were considered in this study. All models were applied using Autodesk inventor model. Static structural analysis was performed using ANSYS to conclude at the best fenestration. Results showed that for Ti-6Al-4V material, design with many loop fenestration has the lowest stress than others, with the result obtained is 495.46 MPa. However, the artificial hip stem with slot fenestration has the smallest deformation with the least difference in value compared to other designs with distortion 0.54808 mm. In addition, the design that produced the higher stress von-Msses was big loop fenestration 526,28 MPa. In conclusion, it was found that all four designs indicated lesser stress values than the yield strength.
机译:由钙化,老化或事故引起的永久性髋关节损坏需要使用人工髋关节置换手术进行更换。在生物材料应用中,总髋关节替换(THR)方法是最成功的。商业市场提供了许多类型的人造髋关节。可以选择各种类型的材料和设计以满足患者的需求。其中一个是髋关节茎上的更繁荣类型的设计。就材料而言,钛和不锈钢是常用于髋关节置换的。本文研究了使用有限元分析研究了更新髋关节杆对机械行为的影响。几种臀部设计,即没有更衰减的髋关节,髋关节与更eneStration槽,具有更强壮的髋关节的髋关节大环和髋关节,具有衰生多环的髋关节,有多环。使用Autodesk Inventor模型应用所有型号。使用ANSYS在最佳衰减中结束静态结构分析。结果表明,对于Ti-6AL-4V材料,具有许多环比的设计具有比其它更低的应力最低,结果为495.46MPa。然而,与狭槽更entration的人造髋·阀杆具有最小的变形,其值与具有0.54808mm的其他设计相比的值相比。此外,产生更高的应力von-MSE的设计是大环续变526,28 MPa。总之,发现所有四种设计表明应力较小的应力值比屈服强度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号