In this paper, an evanescent waveguide is employed as sensor for biomedical application especially for post surgery to diagnostic anastomosis leakage (AL) by detecting bacteria in drain fluid. Atomic Layer Deposition (ALD) is used to deposit thin film of TiO2 as waveguide material. We design and fabricate the waveguide in a freestanding configuration in order to obtain evanescent tale in front and back side so that the sensitivity of the sensor is higher than slab waveguide. An optical measurement is carried out to measure the propagation loses by ‘cut back’ method. An annealing at 700°C in oxygen atmosphere for 1 hour is conducted as treatment to improve the optical properties of the material. The results show that the annealing reduces the propagation loss from 6.7dB/cm to 5.4 dB/cm. The sensitivity of the sensor is presented as dB per unit volume percent (% v/v) of IPA diluted in H2O. The sensitivity of the sensor is 1.6 dB/%.
机译:在本文中,一种蒸发波导用作生物医学应用的传感器,特别是通过检测排水液中的细菌来接受手术以诊断吻合缺失(A1)。 原子层沉积(ALD)用于将TiO 2 的薄膜沉积为波导材料。 我们在独立配置中设计和制造波导,以便在前后侧获得渐逝故事,使得传感器的灵敏度高于板坯波导。 进行光学测量以通过&#x2018测量传播损失;切回’ 方法。 在700° C氧气气氛中的退火为1小时进行1小时,以改善材料的光学性质。 结果表明,退火将传播损耗从6.7db / cm降至5.4 db / cm。 传感器的敏感性在H 2 O中稀释的IPA的每单位体积%(%v / v)呈DB。 传感器的灵敏度为1.6 dB /%。