Nanobiomimetic Structured Organo-Metal Devices Direct Rapid Real-time Monitor Atto Molarities of ATP in Biological Specimens

机译:纳米纤维化结构有机金属装置直接快速实时监测ATP在生物标本中的ATP

获取原文

摘要

Real-time monitoring of ATP in biological specimens is a convenient means to monitor the hygiene in healthcare units and for medical devices.Rapid and precise monitoring of ATP has been in strong demand.We report a unique type of nanostructured organo-metalic devices developed,named as Sensor 1,for the purpose of mimicking the active state of Matrix Metalloproteinase-2(MMP-2),which is able to directly interacting with ATP by a heating method,and compared with a manmade activated biomimetic MMP-2 sensor 2.The Cyclic Voltammetry(CV)method,the Chronoamperometry method(CA),and the Open Circuit Potential(OPO)method were used for evaluating the performances under conditions of antibody-free,labeling-free and reagent-free.Sensor 1 detected the current change of ATP in 100ms response time with the Detection of Limits(DOL)0.56 fM over the analytical range 100 aM-400 nM with a relative Pooled Standard Deviation(RPSD)value 0.9%(n=30)in a Tris medium using the CA method.Sensor 2 was able to direct real-time monitor energy change due to ATP in human milk and organic milk specimens for with or without spiking ATP at 100 aM and 60 nM under with or without low and high-level LPS challenges,were presented by the OPO method against standards and the controls.The accuracy results by a recovery method were 94-0.14% and 91-0.16% at 100 aM and 60 nM ATP for the human milk samples compared with organic milk samples of 85-0.2% and 79%-0.2%,respectively using the OPO method.Imprecision RPSD results for the two methods in five cases were 0.16% and 1% for OPO and CA method(n=15 each)for the human milk samples,respectively compared with 0.22% and 0.6% for the organic milk samples using the OPO and the CA method(n=15 each),respectively.
机译:在生物标本中的ATP实时监测是一种方便的方法,可以在医疗单位和医疗设备中监控卫生.RAPID和ATP的精确监测一直处于强烈的需求。我们报告了一种独特的纳米结构有机丝金属装置,为了模仿基质金属蛋白酶-2(MMP-2)的活性状态的目的,其能够通过加热方法直接与ATP直接与ATP相互作用,并与MANMADE活化的生物摩擦MMP-2传感器2相比。循环伏安法(CV)方法,计时法法(CA)和开路电位(OPO)方法用于评估无抗体,无标记和无试剂的条件下的性能检测到电流在100ms响应时间内通过在分析范围内的限制(DOL)0.56 fm的响应时间内的ATP在分析范围内的100m-400nm上检测到三个AM-400nm,使用CA的TRIS介质中的相对汇总的标准偏差(RPSD)值0.9%(n = 30)方法。Sensor 2能够指导通过OPO方法对标准的方法提出了由100M和60nm的有机乳和有机牛奶和有机牛奶标本的实时监测能量变化,有或没有尖刺,有或没有低级别的LPS挑战。对照。通过分别使用85-0.2%和79%-0.2%的有机牛奶样品,恢复方法的恢复方法的准确度为94-0.14%和91-0.16%和60nm ATP,分别为85-0.2%和79%-0.2%的有机乳样品对于人牛奶样品的OPO和Ca方法(N = 15)的五种情况下的两种方法的rPSD结果分别为0.16%和1%,分别为有机牛奶样品的0.22%和0.6%使用OPO和CA方法(每个N = 15)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号