摘要

Ultrasonic guided wave has attracted considerable attention for structural health monitoring (SHM) due to slight propagation loss and sensitivity to damage. However, the location imaging accuracy reduces hugely as the guided wave is often affected by the reflection of the structure boundary and system noise. In this paper, an improving method was established, in which the distance coefficient and the time coefficient were proposed to select and intercept high signal noise ratio data from all experimental data. The effectiveness of the proposed method was evaluated experimentally with sensors array of different square areas. The experiment result revealed that the location imaging accuracy and efficiency were improved more than 50% and 30% respectively by using the improving method, which shown to offer significant performance advantages for SHM.
机译:由于轻微的传播损失和对损坏的敏感性,超声波引导波引起了结构性健康监测(SHM)的相当关注。然而,定位成像精度大幅减少,因为导向波通常受到结构边界的反射和系统噪声的影响。在本文中,建立了一种改进方法,其中提出了距离系数和时间系数来选择和拦截来自所有实验数据的高信号噪声比数据。通过不同平方区域的传感器阵列实验评估所提出的方法的有效性。实验结果表明,通过使用改进的方法分别提高了50%和30%的位置成像精度和效率,这表明为SHM提供了显着的性能优势。