首页> 外文会议>TIM-17 Physics Conference >Monte Carlo Simulations and Measurements for Efficiency Determination of Lead Shielded Plastic Scintillator Detectors
【24h】

Monte Carlo Simulations and Measurements for Efficiency Determination of Lead Shielded Plastic Scintillator Detectors

机译:蒙特卡罗模拟和效率测定铅屏蔽塑料闪烁器探测器的测量

获取原文

摘要

The plastic scintillators are used in different areas of science and technology. One of the use of these scintillator detectors is as beam loss monitors (BLM) for new generation of high intensity heavy ion in superconducting linear accelerators. Operated in pulse counting mode with rather high thresholds and shielded by few centimeters of lead in order to cope with radiofrequency noise and X-ray background emitted by accelerator cavities, they preserve high efficiency for high energy gamma ray and neutrons produced in the nuclear reactions of lost beam particles with accelerator components. Efficiency calculation and calibration of detectors is very important before their practical usage. In the present work, the efficiency of plastic scintillator detectors is simulated using FLUKA for different gamma and neutron sources like, ~(60)Co, ~(137)Cs and ~(238)Pu-Be. The sources are placed at different positions around the detector. Calculated values are compared with the measured values and a reasonable agreement is observed.
机译:塑料闪烁体用于不同的科学和技术领域。这些闪烁器检测器的使用之一是作为超导线性加速器中新一代高强度重离子的光束损耗监视器(BLM)。以相当高的阈值在脉冲计数模式下操作,并屏蔽厘米的铅,以应对加速器腔发射的射频噪声和X射线背景,它们保持高能量伽马射线和中子在核反应中产生的高效率丢失带加速器组件的束粒子。探测器的效率计算和校准在实际使用之前非常重要。在目前的工作中,使用Fluka为不同的伽马和中子源模拟塑料闪烁探测器的效率,如,〜(60)CO,〜(137)CS和〜(238)PU。该来源放置在探测器周围的不同位置。计算值与测量值进行比较,并且观察到合理的协议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号