I. Introduction Accurate and reliable electron property measurements are essential for understanding many different plasma phenomena, such as, particle collisions, reactions and plasma-surface interactions. Langmuir probes are widely used in low temperature plasma for electron temperature T_e and density n_e measurements because of the relative simplicity of the experimental technique, as well as, providing a localised measurement. However, there is no satisfactory theory for the case of magnetised plasma because cross-field transport mechanisms are poorly understood [1]. Consequently, there is difficulty modelling transport anisotropy and voltage drops consumed by plasma or sheath impedances outside of the probe sheath.
机译:I.引言准确可靠的电子特性测量对于了解许多不同的血浆现象,例如颗粒碰撞,反应和等离子体相互作用至关重要。 Langmuir探针广泛用于电子温度T_E的低温等离子体和密度N_E测量,因为实验技术的相对简单,以及提供局部测量。然而,由于磁化等离子体的情况没有令人满意的理论,因为跨场传输机制理解得很差[1]。因此,难以在探针护套外部的等离子体或鞘障碍消耗的传输各向异性和电压下降。