According to the signal characteristics of power quality disturbances, a detection and classification method based on S-transform is proposed. The S-transform module matrix is used to detect and classify power quality disturbance signal. Eight disturbance signals (voltage sag, voltage swell, momentary interruption, voltage spike, voltage notch, harmonic, inter-harmonic and oscillatory transients) which influence power quality have been simulated. The results show that the method can be used to localize the disturbance time and duration precisely and classify them simply.
机译:根据电能质量扰动的信号特性,提出了一种基于S转换的检测和分类方法。 S转换模块矩阵用于检测和分类电源质量扰动信号。已经模拟了影响功率质量的八个扰动信号(电压凹槽,电压膨胀,瞬时中断,电压尖峰,谐波,谐波,谐波,谐波,谐波,谐波横截面横振荡瞬态。结果表明,该方法可用于本地化干扰时间和持续时间,并简单地对它们进行分类。