首页> 外文会议>International Conference on Advanced Electronic Materials, Computers and Materials Engineering >Failure Analysis on Leakage of Brass Condenser Tube in Thermal Power Plant
【24h】

Failure Analysis on Leakage of Brass Condenser Tube in Thermal Power Plant

机译:火黄铜电气管中黄铜冷凝器管泄漏的失效分析

获取原文

摘要

The corrosion failure analysis of the brass tube in a power plant condenser was conducted by the methods of chemical composition analysis, macro morphology inspection of the leakage point, metallurgical examination, scanning electron microscope and energy spectrum analysis etc. The results indicated that the failure of the brass tube was due to the erosion of the internal surface. The zinc content in the etching pits decreased obviously and dezincification corrosion could be classified. Some suggestions for anti-corrosion measures of the brass tubes were put forward.
机译:通过化学成分分析,泄漏点,冶金检查,扫描电子显微镜和能谱分析等化学成分分析,宏观形态检查的方法进行了电厂冷凝器中黄铜管的腐蚀失效分析。结果表明失败黄铜管是由于内表面的腐蚀。蚀刻凹坑中的锌含量明显下降,并且可以分类脱锌腐蚀。提出了对铜管管的防腐措施的一些建议。