Heat exchanger network retrofit plays an important role in energy saving in process industry. Many design methods for the retrofit of heat exchanger networks have been proposed during the last three decades. Conventional retrofit methods rely heavily on topology modifications which often result in a long-retrofit duration and high initial costs. Energy or heat recovery can be performed using heat exchanger (HE) in heat exchanger network (HEN). In the existing HEN, some of energy is wasted due to unproper HEN design. Killer Whale Algorithm (KWA) was used to solve the optimization problem.
机译:热交换器网络改造在工艺业中节能中起着重要作用。在过去三十年中已经提出了许多用于热交换器网络改造的设计方法。传统的改装方法严重依赖于拓扑修改,这些修改通常导致长改装持续时间和高初始成本。可以在热交换器网络(母鸡)中使用热交换器(HE)来执行能量或热回收。在现有的母鸡中,由于母鸡的设计,一些能量被浪费。杀手鲸算法(KWA)用于解决优化问题。