首页> 外文会议>Conference on Active Flow and Combustion Control >Experimental Study on the Alteration of Cooling Effectivity Through Excitation-Frequency Variation Within an Impingement Jet Array with Side-Wall Induced Crossflow
【24h】

Experimental Study on the Alteration of Cooling Effectivity Through Excitation-Frequency Variation Within an Impingement Jet Array with Side-Wall Induced Crossflow

机译:侧壁诱导横向辐射射击阵列激发频率变化改变冷却效率改变的实验研究

获取原文

摘要

The influence of in-phase variation of the excitation frequency of a 7 by 7 impinging jet array between f = 0 and 1000 Hz on the cooling effectivity is investigated experimentally. Liquid crystal thermography is employed to measure a 2-dimensional wall-temperature distribution, which is used to calculate the local Nusselt numbers and evaluate the global and local heat transfer. The cooling effectivity of the dynamic approach is determined by comparison with corresponding steady blowing conditions. The results show that the use of a specific excitation frequency allows a global cooling effectivity increase of more than 50%.
机译:实验研究了在F = 0和1000Hz之间撞击射流阵列的7次激发频率的相位频率的影响。采用液晶热成像来测量二维壁温度分布,用于计算局部采用数字并评估全球和局部传热。通过与相应的稳定吹风条件进行比较来确定动态方法的冷却效果。结果表明,使用特定的激励频率允许全球冷却效率增加超过50%。