首页> 外文会议>International Conference on Thermofluids >The effects of liquid-suction heat exchanger on the performance of a split air conditioner using R22 under various evaporating temperature
【24h】

The effects of liquid-suction heat exchanger on the performance of a split air conditioner using R22 under various evaporating temperature

机译:液吸热交换器在各种蒸发温度下使用R22使用R22的分流空调性能的影响

获取原文

摘要

An experimental study on the effect of the liquid-suction heat exchanger on the performance of a split air conditioner using R22 has been conducted. The air conditioning machine has been tested under various evaporating temperature, from -5C to +4°C. The test showed that the use of LSHX increases the superheat, discharge temperature, and discharge pressure. It is also shown that the LSHX has no significant effect on the cooling capacity and increases the work of compression, resulting in the lower COP and EER. It signifies that the LSHX is only useful for the safe operation of compressor rather than for improving the cooling performance.
机译:已经进行了对液吸热交换器对使用R22的分割空调性能的实验研究。空调机已经在各种蒸发温度下测试,从-5℃至+ 4℃进行测试。该测试表明,LSHX的使用增加了过热,放电温度和排出压力。还表明,LSHX对冷却能力没有显着影响,并增加压缩的工作,导致下部警察和eer。它表示LSHX仅适用于压缩机的安全操作,而不是用于提高冷却性能。