首页> 外文期刊>Case Studies in Thermal Engineering >Room air conditioning performance using liquid-suction heat exchanger retrofitted with R290
【24h】

Room air conditioning performance using liquid-suction heat exchanger retrofitted with R290

机译:使用装有R290的液体抽吸热交换器的房间空调性能

获取原文
           

摘要

In this paper, a study of room air conditioning performance when using a liquid-suction heat exchanger retrofitted with R290 has been carried out with the aim of determining the influence of LSHX and R290 in terms of refrigeration effect, power consumption, COP, and heat exchanger effectiveness. A liquid-suction heat exchanger (LSHX) with length of 178?mm was designed and installed in air conditioning pipelines. The RAC used is a split-type with input power of 395 W and initial refrigerant R22. The experiment was conducted on two system conditions with 6 tests each. The results showed that LSHX provides an advantage in improving the energy efficiency of the standard RAC systems. Energy savings and increased COP can be as much as 27.69% and 38.29%. The adoption of R290 also helps reduce the potential of ozone depletion and global warming. It can be concluded that the combination of LSHX and R290 can produce better performance.
机译:在本文中,为了确定LSHX和R290在制冷效果,功耗,COP和热量方面的影响,已经进行了研究,研究了使用装有R290的液体抽吸热交换器时的房间空调性能。交换器的有效性。设计了长度为178?mm的吸液热交换器(LSHX),并将其安装在空调管道中。所用的RAC是分体式的,输入功率为395 W,初始制冷剂为R22。实验是在两个系统条件下进行的,每个条件进行6个测试。结果表明,LSHX在提高标准RAC系统的能效方面具有优势。节能和提高的COP分别高达27.69%和38.29%。 R290的采用还有助于减少臭氧消耗和全球变暖的可能性。可以得出结论,LSHX和R290的组合可以产生更好的性能。