首页> 外文会议>Annual International Conference on Material Science and Engineering >The measuring method for actual total magnification of metallographic microscope — digital image method
【24h】

The measuring method for actual total magnification of metallographic microscope — digital image method

机译:金相显微镜实际总放大率的测量方法 - 数字图像方法

获取原文

摘要

In this paper, taking MM6 metallographic microscope 160x as an example, one kind of new method is studied on measuring actual total magnification of metallographic microscope by measuring digital images, the digital image is virtual image viewed through eyepiece of microscope and acquired by digital camera instead of eyes. Results show: 1) The digital images of 5/100 ocular micrometer and 1/100 stage micrometer in the eyepieces of microscope are acquired. The digital images of the 5 grade gauge block, which is 5mm length and is from camera 250 mm, are acquired in the same acquiring conditions. The lengths of the ocular micrometer and gauge block in the digital image are measured, and then the magnification of eyepieces is calculated. The lengths of the ocular micrometer and stage micrometer in the same digital image are measured, and then the magnification of objectives and tube factor is calculated. The actual total magnification of metallographic microscope is the product of magnification of eyepieces and magnification of objectives and tube factor; 2) For 160 x magnification of MM6 metallographic microscope, the measurement result of actual total magnification are stated as: 154.8 x, U=2.8x, k=2, and the actual relative deviation is-3.2%. 3)The digital image measuring method for actual total magnification of metallographic microscope can be a standardized method.
机译:本文采用MM6金相显微镜160x作为示例,研究了一种通过测量数字图像测量金相显微镜的实际总放大率的一种新方法,数字图像是通过显微镜目镜观察的虚拟图像,而是由数码相机获取眼睛。结果表明:1)获取5/100眼镜千分尺的数字图像和1/100级微米在显微镜目镜中。在相同的获取条件下获取5米长度长度和来自相机250mm的5级规格块的数字图像。测量了数字图像中的眼睛千分尺和规格块的长度,然后计算目镜的放大率。测量同一数字图像中的眼睛千分尺和阶段千分尺的长度,然后计算物镜和管因子的放大率。金相显微镜的实际总放大率是目镜放大和物镜和管子因子放大的产物; 2)对于160×MM6金相显微镜的倍率,实际总放大率的测量结果表示为:154.8 x,u = 2.8x,k = 2,实际相对偏差为-3.2%。 3)用于金相显微镜的实际总放大率的数字图像测量方法可以是标准化的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号