The surface modification of biomaterial Mg-4.0Zn-1.5Sr alloy has been done by means of laser surface processing combining alkaline treatment process, as well as the biocompatibility of Mg-4.0Zn-1.5Sr alloy with and without coatings has been analyzed comparatively. The results indicate that the optimal parameters of laser surface processing are that the power is 3 kW, the current 200A, the width 1mm, the defocus amount 135mm and the scanning speed 1mm/s. The optimal parameters of alkaline treatment are that the solution is NaOH, the concentration 0.5 mol/L, the temperature 80 °C and the time 12 h. After alkaline treatment the surface is smooth and compact. The hemolysis rate of 1 d, 3 d, 5 d for uncoated alloy is 1.04%, 0.8% and 4.56%, respectively, which is less than 5%, and for Mg-4.0Zn-1.5Sr alloys with coated of the laser combining alkaline treatment, the hemolysis rate of 1 d, 3 d, 5 d is 0.62%, 1.24% and 0.83% respectively, which is also less than 5%. Therefore, the phenomenon of hemolysis for the alloy with and without coated will not occur. In addition, HR on coated with the laser combining alkaline treatment have larger decline, and less volatility than that without coated, which is express that surface treatment of the alloy has more application prospects. RGR value with coated of laser combining alkaline treatment is 105.7%, 106.0%, 110.4%, respectively which cultivation for 1 d, 3 days, 5days and slightly higher than that of without coated, which isl00%, 108.8% and 101.8%, respectively. According the standard of cell cytotoxicity, for the alloy with and without coated it is zero level cytotoxicity, suitable for used of biomaterial.
机译:通过混合碱性处理方法的激光表面处理完成了生物材料Mg-4.0Zn-1.5SR合金的表面改性,以及Mg-4.0Zn-1.5Sr合金的生物相容性,并且已经相对分析了涂层。结果表明,激光表面处理的最佳参数是功率为3 kW,电流200a,宽度1mm,散焦量135mm和扫描速度为1mm / s。碱性处理的最佳参数是溶液是NaOH,浓度0.5mol / L,温度80℃和12小时的时间。碱性处理后,表面光滑且紧凑。用于未涂合合金的1d,3d,5d的溶血率分别为1.04%,0.8%和4.56%,分别小于5%,并且对于涂覆激光结合的Mg-4.0zn-1.5sr合金碱性处理,1d,3d,5d,5d,5d的溶血率分别为0.62%,1.24%和0.83%,其也小于5%。因此,不会出现具有和不含涂覆的合金的溶血现象。此外,涂有激光结合碱性处理的HR具有较大的下降,并且比没有涂覆的不掺杂的挥发性较少,这表达了合金的表面处理具有更多的应用前景。具有激光结合碱性处理的RGR值分别为105.7%,106.0%,110.4%,分别为1d,3天,5天,略高于没有涂层的培养,分别为1%,含量,108.8%和101.8% 。根据细胞细胞毒性的标准,对于具有且不涂覆的合金,其是零水平细胞毒性,适用于使用生物材料。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号