摘要

Managing electricity breakdown is vital since an outage causes economic losses for customers and the utility companies. However, electricity breakdown is unavoidable due to some internal or external factors beyond our control. Electricity breakdown on overhead lines tend occur more frequently because it is prone to external disturbances such as animal, overgrown vegetation and defective pole top accessories. In Sarawak Energy Berhad (SEB), majority of the network are composed of overhead lines and hence, is more prone to failure. Conventional method of equipment inspection and fault finding are not effective to quickly identify the root cause of failure. SEB has engaged the use of corona discharge camera as condition-based monitoring equipment to carry out condition based inspection on the line in order to diagnose the condition of the lines prior to failure. Experimental testing has been carried out to determine the correlation between the corona discharge count and the level of defect on line insulator. The result shall be tabulated and will be used as reference for future scanning and diagnostic on any defect on the lines.
机译:由于中断为客户和公用事业公司带来经济损失,管理电力故障至关重要。但是,由于我们控制超出了一些内部或外部因素,电力故障是不可避免的。在架空线上的电力故障趋于更频繁地发生,因为它易于外部干扰,例如动物,过度植被和有缺陷的杆顶配件。在沙捞越能源Berhad(SEB)中,大多数网络由架空线组成,因此易于失败。传统的设备检验方法和故障发现无效快速识别失败的根本原因。 SEB已将电晕放电摄像机作为条件为基础的监控设备,以便在线进行基于条件的检查,以便在故障之前诊断线路的状况。已经进行了实验测试以确定电晕放电计数与线绝缘体上缺陷水平之间的相关性。结果应制成,将用作未来扫描和诊断线上的任何缺陷的参考。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号