首页> 外文会议>Maghreb Days of Material Sciences Conference >Improvement of Direct Torque Control by using a Space Vector Modulation Control of Three-Level Inverter
【24h】

Improvement of Direct Torque Control by using a Space Vector Modulation Control of Three-Level Inverter

机译:三电平逆变器空间矢量调制控制改进直接扭矩控制

获取原文

摘要

The performances of Direct Torque Control (DTC) of Induction machine are highly related to the inverter used therewith. The purpose of this paper is to highlight the efficiency of the space vector modulation (SVM) control of three level inverter associated with the direct torque control. The first part of this work is devoted to present the mathematical models of the DTC associated with 2-levels inverter then 3-levels inverter. Simulations on Matlab/Simulink will allow a comparative study to highlight advantages of the use of three levels inverter. The second part is devoted to the improvement of the DTC associated with a 3-levels inverter by application of the space vector modulation strategy (SVM) in order to manage the switching frequency and reduce harmonics. The efficiency of this solution will be attested by simulation on Matlab/Simulink.
机译:感应机的直接扭矩控制(DTC)的性能与其使用的逆变器高度相关。本文的目的是突出与直接扭矩控制相关的三个电平逆变器的空间矢量调制(SVM)控制的效率。本工作的第一部分致力于呈现与2级逆变器相关的DTC的数学模型,然后是3级逆变器。 MATLAB / SIMULINK的模拟将允许比较研究突出使用三级逆变器的优点。通过应用空间矢量调制策略(SVM)来致专用于改善与3级逆变器相关联的DTC,以管理开关频率并减少谐波。通过在MATLAB / SIMULINK上模拟来证明该解决方案的效率。

著录项