首页> 外文会议>US Combustion Meeting >Hyperspectral Imaging Diagnostics of a Scramjet Combustor Cavity
【24h】

Hyperspectral Imaging Diagnostics of a Scramjet Combustor Cavity

机译:Scramjet燃烧室腔的高光谱成像诊断

获取原文

摘要

Spatially resolved water concentration and temperature values are presented for a scramjet cavity burning ethylene fuel. A range of fueling rates are explored. Data was captured using an imaging Fourier transform spectrometer and interpreted through the application of spectroscopic modeling. First, averaging an ensemble of measurements yields high-resolution, wide-band spectra at each pixel of the image. Then, these spectra are modeled using the HITEMP database. This work demonstrates IFTS is a viable combustion diagnostics tool in high-speed combustion. Spatially resolved scalar values can be measured using a single "point-and-shoot" type instrument and a single look-angle. Continued research toward improving the physics-based modeling, specifically the effects of line-of-sight averaging, is still needed. This work, however, continues the use of IFTS on relevant combustion platforms.
机译:呈现空间分离的水浓度和温度值用于燃烧乙烯燃料。探索了一系列燃料率。使用成像傅里叶变换光谱仪捕获数据,并通过光谱造型的应用解释。首先,平均测量的集合产生高分辨率,在图像的每个像素处产生高分辨率宽带谱。然后,使用HITEMP数据库建模这些光谱。这项工作表明IFTS是高速燃烧中可行的燃烧诊断工具。可以使用单个“点和拍摄”型仪器和单个视角来测量空间分辨的标量值。仍然需要继续研究改善基于物理学的建模,特别是视图平均的影响。然而,这项工作继续使用IFTS在相关的燃烧平台上。