This article describes, through the presentation of five cases-history, technological advances that the Authors together with Tunneling Contractors devised for coping with adverse geotechnical conditions. It is believed that by introducing these new elements in a method that has proven its value in Italy and abroad for the last 40 years, the umbrella arch method, due to its versatility and simplicity, can become a universal method for conventional tunneling in very poor ground conditions. After a description of common faults and mistakes in applying the method, 5 projects are presented which demonstrate that self-drilling pipes give excellent results in terms of performance a zero volume loss, while, function of the ground conditions the various grouting mixtures used, such as expansive jet-injected cement-base grouts and bi-component resins, extend the use of the umbrella-arch in variety of grounds even in presence of water-bearing lenses. The case-histories provide successful applications in different conditions.