A new method was studied for the determination of ZrO_2 and TiO_2 in alkali-resistant fiberglass mesh by ICP-AES. The sample was pretreated by acid-soluble and alkali-fusion methods. The corresponding concentration of three times of standard deviation (3S) was used to calculate the detection limit of the method, and the detection limit was from 0.0018% to 0.0047%. The corresponding concentration of ten times of standard deviation (10S) was used to calculate the quantitation limit of the method, and the limit of quantitation was from 0.0060% to 0.016%. The relative standard deviations (RSDs (n=6)) of the test were from 0.60% to 0.78%. Compared to standard method, absolute error was less than 0.2% and the relative error was less than 2.0%. The results showed that the method can be used for simultaneous determination of ZrO_2 and TiO_2 in alkali-resistant fiberglass mesh., with fast analysis and reliable results.
机译:研究了通过ICP-AES在耐碱玻璃纤维网中测定ZrO_2和TiO_2的新方法。通过酸溶和碱熔化方法预处理样品。使用三次标准偏差(3S)的相应浓度来计算该方法的检测限,检测限为0.0018%至0.0047%。使用10次标准偏差(10s)的相应浓度来计算该方法的定量限,但定量限为0.0060%至0.016%。测试的相对标准偏差(RSDS(n = 6))为0.60%至0.78%。与标准方法相比,绝对误差小于0.2%,相对误差小于2.0%。结果表明,该方法可用于同时测定耐碱玻璃纤维网中的ZrO_2和TiO_2。,快速分析和可靠的结果。