首页> 外文会议>ISES EuroSun 2014 Conference >Towards Low Carbon Homes – Measured Performance Of Four Passivhaus Projects In Scotland
【24h】

Towards Low Carbon Homes – Measured Performance Of Four Passivhaus Projects In Scotland

机译:朝向低碳家庭 - 苏格兰四个乘法项目的表现

获取原文

摘要

This paper will describe the results of a 2-year monitoring programme of 4 Passivhaus dwellings in Scotland. The dwellings, part of a group of 8 houses, are built in a rural location in the South of Scotland to Passivhaus standards for private rent. Construction uses an offsite timber panel system. The dwellings rely on solar thermal hot water heating, backed up by a small biomass stove, which both feed a hot water cylinder. Ventilation and heating is via a Mechanical Ventilation Heat Recovery (MVHR) system, with a post heater from the water store. In theory therefore these buildings are zero carbon in terms of space and water heating. The dwellings have been monitored for a two-year period, gathering detailed data on internal environmental conditions, and energy use, including sub-metered electrical use, along with qualitative data from interviews with the occupants and design team. The wood fuel sources have also been tested for energy content and carbon factors. Other fabric tests such as thermography, u-value testing and airtightness have been conducted. This paper will report on the results of these tests and monitoring and describe the performance of these buildings in practice. In general the performance is very good, but significant differences in occupant behaviour are noted that can affect this, and the importance of incidental gains from non-regulated energy use from electrical consumption, which may undermine the zero carbon targets and which can contribute to overheating, are discussed, as is the relative performance of the MVHR system.
机译:本文将描述苏格兰4张乘客住宅的2年监测计划的结果。住宅,一组8个房屋的一部分,建于苏格兰南部的农村地点,以私人租金的Passivaus标准。施工采用异地木材面板系统。住宅依靠太阳能热热水加热,由小型生物量炉灶备份,两者都喂养热水缸。通风和加热是通过机械通风热回收(MVHR)系统,与水储存的后加热器。因此,在空间和水加热方面,这些建筑物是零碳。住宅已被监测为期两年,收集有关内部环境条件的详细数据,以及包括子计量电气用途,以及与乘员和设计团队采访的定性数据。木材燃料源也已经测试了能量含量和碳因子。已经进行了其他织物测试,如热成像,U值测试和气密性。本文将报告这些测试和监测的结果,并在实践中描述了这些建筑的表现。一般来说,性能非常好,但注意到占用行为的显着差异,这可能会影响这一点,并且偶然收益从非监管能源使用的偶然的收益可能会破坏零碳目标,并且可以有助于过热,被讨论,也是MVHR系统的相对性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号