In this study we compared two fixed mesh methods of modeling the electrical and thermal effects produced by water vaporization: the enthalpy method and the water fraction method in radiofrequency ablation (RFA). The results showed the performance of both methods to be qualitatively similar in terms of temperature distributions and impedance evolution. The main difference between the methods was the time at which impedance started to rise. Results suggest that the two methods offer equivalent results in RFA modeling. However, since the enthalpy method has one less problem to be solved (dynamic volume fraction of liquid water in the tissue) it is less complex, has a lower computational cost and therefore seems to be more suitable for modeling RFA with dry or internally cooled electrodes, i.e. those in which there is no interstitial saline infusion.
机译:在这项研究中,我们比较了两种固定的网格方法的建模通过水蒸发产生的电气和热效应:射频消融(RFA)中的焓方法和水分分数法。结果表明,在温度分布和阻抗演化方面,两种方法的性能具有定性相似。方法之间的主要区别是阻抗开始上升的时间。结果表明,这两种方法在RFA建模中提供了等效结果。然而,由于焓方法具有较少的问题(组织中的液体水的动态体积分数),因此复杂的较低,因此具有较低的计算成本,因此似乎更适合于用干燥或内部冷却的电极建模RFA ,即没有间质性盐水输注的那些。