Measured Cooling Season Results Relating the Impact of Mechanical Ventilation on Energy, Comfort, and Indoor Air Quality in Humid Climates

机译:测量的冷却季结果导致机械通气对能量,舒适度和室内空气质量的影响有关的影响

获取原文

摘要

In Florida, residential whole house mechanical ventilation is not required by code and market penetration of ASHRAE 62.2 compliant mechanical ventilation systems is poor. There is concern amongst regional builders and contractors around implications of mechanically introducing humid outside air compared to the indoor air quality benefits, which many feel are not adequately documented or demonstrated. These implications include impact on energy use, comfort, durability, and cost. This paper describes results from a study in Gainesville, FL relating the impact of ventilation on these parameters. Ten homes built and occupied in the 2009-2010 timeframe with HERS Index < 65 have been under evaluation since June 2013. All ten homes were built with a central fan integrated supply ventilation system (CFIS) delivering an average of 35 cubic feet per minute (cfm) of outside air during heating/cooling operation only, and average 3.6 ACH50. As part of this study, a bathroom exhaust fan in each home was replaced with a larger capacity fan capable of exhausting a continuous 60 cfm on average, approximating ASHRAE 62.2-2010 requirements. The homes were divided into two cohorts: 6 homes that alternate between the CFIS ventilation system and the continuous exhaust ventilation system every 2 weeks, and 4 homes that operate one of the ventilation systems exclusively (2 homes per system). Monitoring of temperature, relative humidity, CO2 concentration, and space conditioning energy use occurs continuously, while concentrations of formaldehyde, acetaldehyde, TVOC, and NO2 are measured seasonally. Results spanning late June through mid-October 2013 are presented and discussed.
机译:在佛罗里达州,除了Ashrae 62.2的典型机械通风系统差,不需要住宅整体机械通风。与室内空气质量益处相比,区域建设者和承包商之间的涉及机械引入潮湿的外部空气的影响,许多感觉没有充分记录或展示。这些含义包括对能源使用,舒适,耐用性和成本的影响。本文介绍了盖恩斯维尔研究的结果,FL与通气对这些参数的影响有关。十家建成并在2009 - 2010年的时间内与HERS指数<65已根据评估自六月占领2013年十款家庭用中央的风扇集成电源通风系统(CFIS)提供平均立方英尺每分钟35(建CFM)在加热/冷却操作期间外部空气,平均为3.6 ACH50。作为本研究的一部分,每个家庭的浴室排气扇被更大的容量风扇替换,能够平均耗尽连续的60 CFM,近似Ashrae 62.2-2010要求。将家庭分为两架队列:6个家庭,每2周和连续排气通风系统和连续排气通风系统交替,4个家庭专门运营其中一个通风系统(每个系统2个房屋)。连续地监测温度,相对湿度,CO 2浓度和空间调节能量使用,同时季节性地测量甲醛,乙醛,TVOC和NO2的浓度。结果介绍并讨论了跨国公司跨国公司跨越2013年中期的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号