Measured Cooling Season Results Relating the Impact of Mechanical Ventilation on Energy, Comfort, and Indoor Air Quality in Humid Climates

机译:潮湿季节中机械通风对能量,舒适度和室内空气质量影响的实测冷却季节结果

获取原文
获取原文并翻译 | 示例

摘要

In Florida, residential whole house mechanical ventilation is not required by code andrnmarket penetration of ASHRAE 62.2 compliant mechanical ventilation systems is poor. There isrnconcern amongst regional builders and contractors around implications of mechanicallyrnintroducing humid outside air compared to the indoor air quality benefits, which many feel arernnot adequately documented or demonstrated. These implications include impact on energy use,rncomfort, durability, and cost. This paper describes results from a study in Gainesville, FLrnrelating the impact of ventilation on these parameters.rnTen homes built and occupied in the 2009-2010 timeframe with HERS Index < 65 havernbeen under evaluation since June 2013. All ten homes were built with a central fan integratedrnsupply ventilation system (CFIS) delivering an average of 35 cubic feet per minute (cfm) ofrnoutside air during heating/cooling operation only, and average 3.6 ACH50. As part of this study,rna bathroom exhaust fan in each home was replaced with a larger capacity fan capable ofrnexhausting a continuous 60 cfm on average, approximating ASHRAE 62.2-2010 requirements.rnThe homes were divided into two cohorts: 6 homes that alternate between the CFIS ventilationrnsystem and the continuous exhaust ventilation system every 2 weeks, and 4 homes that operaternone of the ventilation systems exclusively (2 homes per system). Monitoring of temperature,rnrelative humidity, CO2 concentration, and space conditioning energy use occurs continuously,rnwhile concentrations of formaldehyde, acetaldehyde, TVOC, and NO2 are measured seasonally.rnResults spanning late June through mid-October 2013 are presented and discussed.
机译:在佛罗里达州,法规不要求住宅全屋机械通风,并且符合ASHRAE 62.2标准的机械通风系统在市场上的普及率很低。与室内空气质量的好处相比,区域建筑商和承包商对机械引入外部潮湿空气的影响感到担忧,许多人认为这没有得到充分的记录或证明。这些影响包括对能源使用,舒适度,耐用性和成本的影响。本文介绍了在盖恩斯维尔进行的一项研究的结果,该调查涉及通风对这些参数的影响。rn自2009年6月以来,在2009-2010年期间建造和居住的HERS指数<65的十所房屋已受到评估。所有十所房屋均建有中央风扇集成式供气通风系统(CFIS)仅在加热/制冷操作期间平均提供每分钟35立方英尺(cfm)的外部空气,平均提供3.6 ACH50。作为这项研究的一部分,每个房屋中的rna浴室排气风扇被替换为能够平均连续排放60 cfm的大容量风扇,接近ASHRAE 62.2-2010的要求。房屋被划分为两个群组:6个房屋在CFIS通风系统和连续排气通风系统每2周一次,并且有4个专门运行该通风系统的房屋(每个系统2个房屋)。持续进行温度,相对湿度,CO2浓度和空间调节能源的使用监测,同时按季节测量甲醛,乙醛,TVOC和NO2的浓度。rn提出并讨论了从6月下旬到2013年10月中旬的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号