Space cooling is a significant energy consumer in office buildings in the subtropical climate zone. An adequate energy policy for indoor spaces should accordingly incorporate both energy conservation and an acceptable level of indoor environmental quality (IEQ). This study investigates the cooling energy consumption for IEQ acceptance in Hong Kong offices adopted for four space-cooling strategies: the ventilation strategies of conventional constant air volume (CAV) systems with a fixed fresh air flow rate; demand-controlled ventilation (DCV) by indoor CO_2 concentration; adaptive comfort temperature (ACT) set-point adjustment; and a combination of DCV and ACT operations. Numerical equations and multiple regression formulae were used to evaluate the cooling energy consumption and IEQ acceptance in the target offices, respectively. The results show that systems equipped with DCV are more energy efficient than conventional CAV systems, while a temperature set-point adjusted between 22°C and 23°C should satisfy the occupants' thermal requirements at a reasonable rate of energy expenditure. Meanwhile, the DCV + ACT method was found to be an effective ventilation strategy in terms of its energy saving potential (21.4%-24.3%) and an "average" IEQ acceptance, as presented in the sample office. The results of this study could be useful for the promotion of energy saving measures with IEQ consideration in air-conditioned office buildings in Hong Kong.
机译:空间冷却是亚热带气候区的办公楼中的重要能源消费者。因此,室内空间的适当能源政策应纳入节能和可接受的室内环境质量水平(IEQ)。本研究调查了四个空间冷却策略采用的香港办事处的IEQ接受的冷却能耗:传统恒定空气量(CAV)系统的通风策略,具有固定的新鲜空气流速;室内CO_2浓度的需求控制的通风(DCV);自适应舒适温度(ACT)设定点调整;以及DCV和ACT操作的组合。使用数值和多元回归公式分别用于评估目标办公室中的冷却能耗和IEQ接受。结果表明,配备DCV的系统比传统的CAV系统更能​​节能,而22°C和23°C的温度设定点应以合理的能源支出率满足乘员的热需求。同时,发现DCV + ACT方法是其节能潜力(21.4%-24.3%)和“平均”IEQ接受的有效通风策略,如样品办公室所示。本研究的结果可用于促进香港空调办公楼IEQ考虑的节能措施。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号