首页> 外文会议>International Conference on Materials, Transportation and Environmental Engineering >Metal Corrosion of Ballast Tank Caused by Electrolytically Treated Ballast Water
【24h】

Metal Corrosion of Ballast Tank Caused by Electrolytically Treated Ballast Water

机译:由电解处理的压载水引起的压载舱的金属腐蚀

获取原文

摘要

The metal corrosion of ballast tank caused by ships' ballast water that has been electrolysed has been studied in the laboratory by means of statically immersing metal sample in treated sea water. Experimental tests show that the corrosion rate in the electrolyzed seawater is larger than that in the natural seawater, but the increment of the corrosion rate is not more than 35% in the first 12 hours in the medium with a 5 mg/L initial chlorine concentration and the corrosion rate will decrease with time.
机译:通过静态浸没在处理的海水中的静态浸没金属样品,在实验室中研究了由船舶压载水引起的船舶压载水引起的压载槽的腐蚀。 实验测试表明,电解海水中的腐蚀速率大于天然海水中的腐蚀速率,但腐蚀速率的增量在培养基中的前12小时内不超过35%,初始氯浓度为5mg / L 腐蚀速率随时间减少。