摘要

Based on the large space factory fire experiment, comparison of fire simulations was researched. A large space fire experiment was done in Huang Shan industrial park. In the study, the temperature of the smoke layer above the fire source was selected as the research object. Then the regional model and field model were established separately. And fire simulations respectively based on the two models were carried out .The results of the simulations were consistent with the experimental results with less 10% relative error. However, the temperature of the regional simulation was higher than the temperature of the field simulation. In the permissible error, both the two simulations can be used for the prediction and testing of the projects.
机译:基于大型空间厂消防试验,研究了火灾模拟的比较。黄山工业园区进行了大型空间消防实验。在研究中,选择了消防源上方的烟雾层的温度作为研究对象。然后单独建立区域模型和现场模型。进行基于两种模型的消防模拟。模拟结果与实验结果一致,实验结果具有较少的相对误差。然而,区域模拟的温度高于场模拟的温度。在允许的错误中,两者都可以用于项目的预测和测试。