This paper reports the experimental results with an open multideck display case with dual air curtain. Manufacturers seek during the design phase of the equipment to certify its suitability to the testing standards with the lowest energy consumption and ensuring food safety. The testing standard ISO 23953 is usually followed to determine the equipment's thermal cooling load. However, some manufacturers use different procedures to set the external air velocity. The thermal cooling load will depend upon it. According to ISO 23953, the mean horizontal air velocity, with the refrigerated display case switched off, shall be 0.2 m/s. Thus, this paper reports the experimental results of tests where the initial procedure of setting the air velocity was performed by two different methods: (1) with the display case cooling on (2) and switched off as required by ISO 23953. The comparison of experimental results for the two conditions (switched off relatively to switched on) provide the quantitative variation of frost formation (-24%) and condensed water (+180%) on the evaporator coil and how this phenomena affects the distribution and magnitudes of air velocity (+7%); inlet (+5.9°C) and outlet temperatures (+5.5°C); the components of the total sensible (+10%) and latent (+15%) heat loads; and the average product temperatures (+176%). The analysis of experimental data provides the necessary basis to conclude that the initial procedure how the air movement is set affects significantly the performance of the equipment under testing. The results show that air movement procedure defined in the standard, although providing a higher thermal cooling load, is the most appropriated since the equipment will be able to operate correctly under more demanding ambient conditions and thus its design provides a better thermal performance.
机译:本文报道以开放的整机货架陈列柜具有双空气帘的实验结果。在设备的设计阶段制造商寻求其适用性认证的检测标准与最低的能源消耗,确保食品安全。测试标准ISO 23953之后通常是,以确定设备的热冷却负载。然而,一些制造商使用不同的程序来设置外部空气流速。热冷却负载将取决于它。根据ISO 23953,平均水平空气速度,与冷藏陈列柜关掉,应为0.2米/秒。因此,本文报道其中通过两种不同的方法进行设定的空气速度的初始过程的试验的实验结果:(1)与在显示情况下冷却所要求的ISO 23953.的比较(2)和关断对于这两个条件的实验结果(关断相对于接通)提供的结霜(-24%)和冷凝水(+ 180%)上的蒸发器盘管的定量变化,并且这种现象如何影响空气速度分布和大小(+ 7%);入口(+ 5.9℃)的温度和出口温度(+ 5.5℃);的总明智(+ 10%)的部件和潜(+ 15%)的热负荷;和平均产品温度(+ 176%)。实验数据的分析提供了必要的基础上断定,初始过程空气移动如何是一套显著影响设备的下测试的性能。结果表明在标准中定义的空气运动过程中,虽然提供了更高的热负荷的冷却,是最拨因为设备将能够更苛刻的环境条件下正确地操作,因此,其设计提供了一个更好的热性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号