首页> 外文期刊>European Journal of Radiology >Image quality performance of liquid crystal display systems: influence of display resolution, magnification and window settings on contrast-detail detection.
【24h】

Image quality performance of liquid crystal display systems: influence of display resolution, magnification and window settings on contrast-detail detection.

机译:液晶显示系统的图像质量性能:显示分辨率,放大率和窗口设置对对比度细节检测的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study was to investigate the combined effects of liquid crystal display (LCD) resolution, image magnification and window/level adjustment on the low-contrast performance in soft-copy image interpretation in digital radiography and digital mammography. In addition, the effect of a new LCD noise reduction mechanism on the low-contrast detectability was studied. Digital radiographs and mammograms of two dedicated contrast-detail phantoms (CDRAD 2.0 and CDMAM 3.4) were scored on five LCD devices with varying resolutions (1-3- and 5-megapixel) and one dedicated 5-megapixel cathode ray tube monitor. Two 5-megapixel LCDs were included. The first one was a standard 5-megapixel LCD and the second had a new (Per Pixel Uniformity) noise reduction mechanism. A multi-variate analysis of variance revealed a significant influence of LCD resolution, image magnification and window/level adjustment on the image quality performance assessed with both the CDRAD 2.0 and the CDMAM 3.4 phantoms. The interactive adjustment of brightness and contrast of digital images did not affect the reading time, whereas magnification to full resolution resulted in a significantly slower soft-copy interpretation. For digital radiography applications, a 3-megapixel LCD is comparable with a 5-megapixel CRT monitor in terms of low-contrast performance as well as in reading time. The use of a 2-megapixel LCD is only warranted when radiographs are analysed in full resolution and when using the interactive window/level adjustment. In digital mammography, a 5-megapixel monitor should be the first choice. In addition, the new PPU noise reduction system in the 5-megapixel LCD devices provides significantly better results for mammography reading as compared to a standard 5-magapixel LCD or CRT. If a 3-megapixel LCD is used in mammography setting, a very time-consuming magnification of the digital mammograms would be necessary.
机译:这项研究的目的是研究液晶显示器(LCD)分辨率,图像放大倍数和窗口/水平调整对数字射线照相和数字乳腺摄影中软拷贝图像解释中低对比度性能的综合影响。此外,研究了新型LCD降噪机制对低对比度可检测性的影响。在五个分辨率不同(1-3和5兆像素)的LCD设备和一个5像素专用阴极射线管监视器上对两个专用的对比度细节体模(CDRAD 2.0和CDMAM 3.4)的数字射线照片和X线照片进行了评分。包括两个5百万像素LCD。第一个是标准的5百万像素LCD,第二个具有新的(每像素均匀性)降噪机制。方差的多变量分析显示,LCD分辨率,图像放大倍率和窗口/水平调整对使用CDRAD 2.0和CDMAM 3.4体模评估的图像质量性能有重大影响。交互式调整数字图像的亮度和对比度不会影响读取时间,而放大至全分辨率会导致软拷贝解释的速度大大降低。对于数字射线照相应用,就低对比度性能和读取时间而言,3百万像素LCD可以与5百万像素CRT监视器媲美。仅当以完全分辨率分析射线照片并使用交互式窗口/水平调整时,才保证使用2兆像素LCD。在数字乳腺摄影中,5兆像素监视器应该是首选。此外,与标准的5像素LCD或CRT相比,在5像素LCD设备中的新型PPU降噪系统为乳腺X线摄影读取提供了更好的结果。如果将3百万像素LCD用于乳腺摄影,则需要非常耗时的数字乳腺摄影放大倍数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号