Waste cooking oil has always been an environment problem in food factories and one method of effect disposing this oil without effecting the environment is to convert it to fatty acid methyl ester (FAME) using small scale pilot plant. The conversion of waste cooking oil with sodium hydroxide as a catalyst in conversional process at 22kHz speed. The reaction of time, molar ratio, speed, catalyst and amount of catalyst will be effect in FAME quality. The quality of biodiesel define is total ester content using gas chromatography. Gas chromatography analysis is a one of technique for identification and quantitation of compounds in a biodiesel sample. From biodiesel sample can identification of contaminants and fatty acid methyl ester. In this research biodiesel sample were analyses using a gas chromatography-flame ionization detector ( Perkin Elmer GC Model Clarus 500) equipped with a DB-5 HT capillary column (0.53mm × 5 m) J&W Scientific. The analytic conditions for ester content were as follow by: column temperature used 210°C, temperature flame ionization detector (FID) of 250°C, pressure of 80kPa, flow carrier gas of 1ml/min, temperature injector of 250°C, split flow rate of 50ml/min, time for analysis 20 minute and volume injected of 1μl. The ester content (C), expresses as a mass fraction in present using formula (EN 14103, 2003a) calculation. Conversion of triglyceride (TG) to FAME using conversional process obtained 96.54% w.t with methanol to oil molar ratio 6:1, 1%w.t acid sulphuric and 1% w.t sodium hydroxide catalyst.
机译:废烹饪油一直在食品工厂的环境问题和效果,而不影响环境设置这种油的一种方法是将其转换为使用小规模试验工厂脂肪酸甲酯(FAME)。的废烹饪用氢氧化钠油作为在22kHz的速度在conversional过程的催化剂的转化。的时间,摩尔比,速度,催化剂和催化剂的量,反应将在FAME的质量的效果。生物柴油的定义的质量是使用气相色谱总酯含量。气相色谱分析技术是识别和化合物的定量生物柴油样品中的一个。从污染物的生物柴油样品罐识别和脂肪酸甲酯。在这项研究中的生物柴油样品均使用配有DB-5 HT毛细管柱(0.53毫米×5米)J&W科学气相色谱 - 火焰电离检测器(珀金埃尔默GC模型的Clarus 500)分析。如下通过用于酯含量的分析条件为:柱温度下使用210℃,温度的火焰离子化检测器的250℃,80kPa的压力(FID),流速为250℃1毫升/ min,温度喷射器的载气,分流流量50毫升/分钟的速率,时间为分析20分钟和体积注射各1μl。酯含量(C),表示作为使用式中存在的质量分数(EN 14103,2003年)的计算。使用conversional过程甘油三酯(TG)以FAME的转换而获得的96.54%w.t用甲醇油摩尔比6:1,1%w.t酸硫酸和1%w.t氢氧化钠催化剂。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号