We propose a dynamic observation concept to pretend aged degradation of water-soluble coolant. The first-hand observation of coolants by a CCD microscope is extremely useful for monitoring the drastic appearance change. The appearance changes of coolant also could be monitored by combining the reflectance changes from the Red, Green and Blue LED lights. The physical process of absorbing light is occurred only at the specific wavelength in the water-soluble coolants. The absorbance at the specific wavelength would become a reliable indicator to predict the controlled condition of water-soluble coolant. Setting up these sensing systems to the machine tools make it possible to observe the coolant dynamically and on real time.
机译:我们提出了一种动态的观察结果来假装随可溶性冷却剂的老化降解。通过CCD显微镜的冷却剂的第一手观察对于监测剧烈外观变化非常有用。通过将来自红色,绿色和蓝色LED灯的反射率变化组合来监测冷却剂的外观变化。吸收光的物理过程仅在水溶性冷却剂中的特定波长处发生。特定波长的吸光度将成为可靠的指示器,以预测水溶性冷却剂的受控条件。将这些传感系统设置为机床,使得可以动态地和实时观察冷却剂。