Carried out fire load survey of exhibition building in Beijing, and obtained a lot of data. On preliminary theoretical studies results the data has been analyzed, and then determined the fire load density standard value 876.21 MJ/m~2, average of 382.97 MJ/m~2. The data is not refused to obey the extreme value I distribution type. In the fire protection design simulation the standard value is suggested to be used.
机译:开展了北京展览建设的火灾负荷调查,并获得了大量数据。在初步理论研究结果中,分析了数据,然后确定了火焰负荷密度标准值876.21 MJ / m〜2,平均为382.97mJ / m〜2。数据不会拒绝遵守极值I分发类型。在防火设计模拟中,建议使用标准值。