The distribution network is mostly the ungrounded neutral system or the resonant grounded system in many countries. Selecting the fault line as soon as possible is of great significance to power systems. This paper proposes a parameter identification method in frequency domain to solve this problem. By using the matrix pencil method to extract frequency-points and their information in zero-sequence voltage and zero-sequence current, spectral leakage in DFT is avoided. With the estimated frequency points, an equation in frequency domain is established which will help to calculate the capacitance value and thus to identify the fault line. This method requires a low sampling rate and has high accuracy. In addition, the frequency-band in this new method is wider than the SFB's frequency-band. Verified by simulation in ATP-EMTP and data from RTDS, the new method is quite effective in fault line selection with an ability to overcome transition resistor and is immune from the impact of arc-suppression.
机译:分销网络主要是未接地的中性系统或许多国家的谐振接地系统。尽快选择故障线对电力系统具有重要意义。本文提出了频域参数识别方法来解决这个问题。通过使用矩阵铅笔方法提取频率点及其中的零序电压和零序电流的信息,避免了DFT中的光谱泄漏。利用估计的频率点,建立频域中的等式,这将有助于计算电容值,从而有助于识别故障线。该方法需要低采样速率并具有高精度。另外,这种新方法中的频带比SFB的频带宽。通过在ATP-EMTP和来自RTD的数据中进行仿真,新方法在故障线选择中非常有效,具有克服过渡电阻的能力,并且免受弧形抑制的影响免疫。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号