DIALux space lighting simulation software is commonly used, in particular, in the designs of lighting environments; however, it is found that simulated data and actual measurements may differ. In order to solve this problem, this study explored the causes of the errors and their feasible solutions. Three methods were applied to mutually verify their credibility in practice; (1) luminance and illuminance instrumental single point measurement; (2) CCD imaging photometer measurement; and (3) DIALux lighting software. The results suggested that the surrounding reflectivity setting within the building of a simulated space is very important, but the actual measurement of the lamp distribution data would affect the simulation results. After knowing how to fix the causes leading to such errors in simulation, simple simulation approaches can be used to calculate the optical parameters, such as illuminance and luminance distribution, that are consistent with the actual measurements.
机译:Dialux空间照明仿真软件常用于照明环境的设计中;然而,发现模拟数据和实际测量可能不同。为了解决这个问题,本研究探讨了错误的原因及其可行的解决方案。应用了三种方法以相互验证其可信度; (1)亮度和照度仪器单点测量; (2)CCD成像光度计测量;和(3)Dialux照明软件。结果表明,模拟空间建筑内的周围反射率设置非常重要,但灯具分布数据的实​​际测量会影响模拟结果。在知道如何修复导致模拟中的原因之后,可以使用简单的仿真方法来计算与实际测量一致的光学参数,例如照度和亮度分布。