首页> 外文会议>International Conference on Civil Engineering, Architecture and Building Materials >Experimental investigation on steel H-beam prestressed with externally high strength steel bars
【24h】

Experimental investigation on steel H-beam prestressed with externally high strength steel bars

机译:外部高强度钢筋预应力钢H梁的实验研究

获取原文

摘要

The external post-tensioning technique has been commonly used in the construction field because it facilitates the analysis of structures and is widely applicable for many types of structures. In this research, 12 steel H-beams were built and tested in terms of the amount of tendon or prestressing force. The results show that the externally prestressing method can increase ultimate bearing capacity of the beams. The prestressing force is the significant factor that influence the strengthening of steel H-beams. However, the amount of deviators cannot significantly influence the bearing capacity.
机译:外部张紧技术通常用于施工领域,因为它有助于结构的分析,并且广泛适用于许多类型的结构。在这项研究中,在肌腱或预应力的数量方面建立并测试了12个钢梁。结果表明,外部预应力方法可以增加光束的最终承载力。预应力力是影响钢H梁强化的重要因素。然而,偏差量不能显着影响承载力。