Based on the temperature monitoring for the double U-tube wells with thermal resistance, numerical simulation researching on two-dimensional temperature field and three-dimensional temperature field was carried out for vertical double U-tube group. Under the condition of 6.5m for horizontal spacing of tube well, the Soil temperature around inner tube wells increases 0.4°C in one year, and 0.24°C for the surrounding tube wells. The paper calculates the increasing temperature of the tube wells, 7.95°C for inner tube wells and 4.70°C for surrounding tube wells. The soil temperature of tube wells is rising with the running time increasing, however, the temperature rate of the soil around inner tube wells is larger than the surrounding tube wells'.
机译:基于对具有热阻的双U管孔的温度监测,对二维温度场和三维温度场进行数值模拟,对垂直双管组进行。在管井水平间距的6.5米的条件下,内管井周围的土壤温度在一年内增加0.4°C,周围管孔为0.24°C。本文计算了管孔的升高温度,7.95°C,用于内管孔,4.70°C用于周围管孔。管孔的土壤温度随着运行时间的增加而上升,然而,内管井周围的土壤的温度率大于周围管孔'。