首页> 外文会议>International Conference on Energy and Environmental Protection >Methods of determining the atmosphere environment impact factors of natural draft cooling towers
【24h】

Methods of determining the atmosphere environment impact factors of natural draft cooling towers

机译:确定天然冷却塔的大气环境影响因素的方法

获取原文

摘要

The ISC SCREEN3 recommend by the existing guidelines cannot support the atmospheric dispersion modeling of the cooling tower discharge, causing the big difference between the current the atmosphere evaluation class and scope for the project of integrated chimney and cooling tower and the actual environmental impact.In this paper, the model austal2000 which is recommended by VDI3784 standard of the clean air standards established in German is used to calculate the ground concentrations of pollutants discharged by cooling towers, and accounting atmospheric environmental impact assessment class and scope of the unity project of smoke and lower according to the specifications of air guidelines reference. The results show that the most of the smoke and tower integration projects' evaluation level should be 2 and the evaluation radius should be more than 15 km, for the projects with emission of larger pollutants, the evaluation level may reach level 1.
机译:通过现有指南推荐的ISC Screen3不能支持冷却塔放电的大气分散建模,导致当前大气评估阶段和集成烟囱和冷却塔项目的范围与实际环境影响之间的巨大差异。这纸张,由VDI3784建议的德国清洁空气标准推荐的型号AUSTAL2000用于计算冷却塔排放的污染物的地面浓度,并占烟雾和烟雾统一项目的大气环境影响评估阶级和范围根据空气指南的规格参考。结果表明,大多数烟雾和塔集成项目的评价水平应为2,评价半径应超过15公里,对于较大的污染物排放的项目,评估水平可能达到1级。