首页> 外文会议>International Conference on Applied Mechanics and Manufacturing Technology >Mechanical properties of several NiTi alloy wires in three-point bending tests
【24h】

Mechanical properties of several NiTi alloy wires in three-point bending tests

机译:三点弯曲试验中几种Niti合金线的机械性能

获取原文

摘要

Objective: To clarify mechanical properties of 14 superelastic NiTi orthodontic wires by threepoint bending tests. Materials and Methods: The three-point bending test was conducted with a midspan deflection rate of 5 mm/min under constant temperature range 36±1°C. Wires were deflected to 3.1 mm. All data were recorded during the unloading process at deflections 3, 2, 1 and 0.5 mm. to simulate the force a wire exerts as a tooth is moved into the dental arch from a position of malocclusion. Results: The delivered forces changed slightly when the deflection varied during loading and unloading. Sentalloy wire applied the lowest continuous force. Conclusions: Commercial wires may not behave similarly due to minor differences in the production process, and force varies greatly from brand to brand. NiTi wire brands must be selected carefully considering the severity of malocclusion and stage of orthodontic treatment.
机译:目的:通过三点弯曲试验阐明14个超弹性NITI正畸线的机械性能。材料和方法:在恒定温度范围为36±1°C的恒定温度范围内以5mm / min的半轴偏转率进行三点弯曲试验。导线偏转至3.1毫米。在卸载过程中记录所有数据,在偏转3,2,1和0.5mm处。为了模拟力,电线作为牙齿施加到牙科弓形中的牙弓。结果:当在装载和卸载过程中偏转时,交付的力略微发生变化。 Sentalloy丝施加了最低的连续力。结论:由于生产过程的微小差异,商业电线可能不会表现得不同,并且力量从品牌到品牌变化很大。必须仔细选择Niti Wire品牌,考虑术语的严重程度和正畸治疗阶段的严重程度。