首页> 外文会议>International Conference on Information Engineering for Mechanics and Materials >The residual stress distribution and fatigue property of TC4 laser-welded joint treated by laser shock peening
【24h】

The residual stress distribution and fatigue property of TC4 laser-welded joint treated by laser shock peening

机译:激光震动治疗TC4激光焊接接头的残余应力分布及疲劳性能

获取原文

摘要

The absence of highly tensile residual stress which distributed in laser welded joint is primary factor of decreasing fatigue life. Laser Shock Peening (LSP) experiments were conducted on TC4 laser welded joints of 2.5mm thickness, using circular laser spot with pulse duration of 10ns, laser power density of 7.2GW/cm~2 and overlapping ratio of 37.5%. Surface residual stress distribution were studied under LSP of one layer, three layers and five layers. Surface tensile residual stresses converted to compressive residual stresses on LSP area, and compressive residual stresses along longitudinal direction were greater than along transverse direction. The amplitude of compressive residual stress were greatly relative to number of LSP layer. Fatigue life of specimens treated by three layers increased 50% in comparison to untreated specimens (maximum stress: 750MPa, stress ratio: 0.06). In a word, LSP could adjust residual stress field of laser welded joint, and it is an alternative technology to be potential to substantially improve fatigue performance.
机译:在激光焊接接头中分布的缺乏高度拉伸残余应力是降低疲劳寿命的主要因素。激光冲击喷丸(LSP)实验在TC4激光焊接接头上进行2.5mm厚度,使用脉冲持续时间为10ns,激光功率密度为7.2gw / cm〜2的激光功率密度,重叠率为37.5%。在一层,三层和五层的LSP下研究了表面残余应力分布。表面拉伸残余应力转化为LSP区域上的压缩残余应力,并且沿纵向的压缩残余应力大于横向。压缩残余应力的幅度相对于LSP层的数量大大。与未处理的试样相比,由三层处理的标本的疲劳寿命增加了50%(最大应力:750MPa,应力比:0.06)。总之,LSP可以调节激光焊接接头的残余应力场,并且是替代技术,可以显着提高疲劳性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号