摘要

According to fire station of Tuandao road along to the Yunnan road tunnel of Qingdao Cross-harbor Tunnel Guide Line Project, the blasting vibration test was carried on. This building is three-storied brick-and-concrete building. Then monitoring data of particle vibration velocity was analysised and researched. The results showed that there is magnifying effect of vertical vibration velocity on the roof of the building, but its value is lesser than particle vibration velocity of the first layer. Horizontal tangential vibration velocity was existed on the central of the building. However there was no magnifying effect of horizontal radial vibration velocity. And its value is decreased rapidly from the first layer to the second layer, and then other floors basically keep steady.
机译:根据拓岛路的消防局沿着青岛横港隧道隧道引导线项目的云南路隧道,进行了爆破振动试验。这栋建筑是三层砖块混凝土建筑。然后分析和研究粒子振动速度的监测数据。结果表明,建筑物顶部垂直振动速度的放大效果,但其值小于第一层的粒子振动速度。在建筑物的中央存在水平切向振动速度。然而,没有水平径向振动速度的放大效果。并且其值从第一层到第二层迅速下降,然后其他楼层基本上保持稳定。