Based on the characteristic of cooler frame, the finite element model of air cooler frame is established using ANSYS software. Equivalent static load method and response spectrum method were used for the seismic performance analysis of cooler frame. The equivalent static load is applied at the center of gravity of various masses using MPC184 rigid beam for transferring the load. The deformation and stress of cooler using equivalent static load method are larger than that of cooler using spectrum response method. For this reason, it can be said that the equivalent static load method is more conservative. At last the deformations and stresses of cooler frame using two methods are checked by ASME AG-1 specification. The results showed that the deformation and stress of cooler frame meet the requirements.
机译:基于冷却器框架的特性,使用ANSYS软件建立空气冷却器框架的有限元模型。等效静载方法和响应谱法用于冷却器框架的地震性能分析。使用MPC184刚性光束在各种肿块的重心施加等效静载荷,用于转移负载。使用等效静载方法的冷却器的变形和应力大于光谱响应法的冷却器的变形和应力。因此,可以说等效的静载方法更保守。最后,通过ASME AG-1规范检查了使用两种方法的冷却器框架的变形和应力。结果表明,冷却器框架的变形和应力符合要求。