首页> 外文会议>ASME/JSME thermal engineering joint conference >EFFECT OF COOLING WATER TEMPERATURE ON IMPINGING JET HEAT TRANSFER ON HOT STEEL PLATE
【24h】

EFFECT OF COOLING WATER TEMPERATURE ON IMPINGING JET HEAT TRANSFER ON HOT STEEL PLATE

机译:冷却水温对热钢板撞击喷射热传递的影响

获取原文

摘要

Water impinging jet has been widely used in a variety of engineering applications; especially in the hot steel cooling of steelmaking processes and heat treatment in hot metals. The effects of cooling water temperature on water impinging jet cooling are mainly investigated for hot steel plate cooling in this study. The heat flux are measured by a novel experimental technique that has a function of high-temperature heat flux gauge in which test block assemblies are used to measure the heat flux distributions on the hot surface. The water impinging jet is produced by a straight pipe nozzle and experiments are performed at fixed water flow rate and fixed nozzle-to-target spacing. The results show that effects of water temperature on impinging jet transfer characteristics are presented for five different water temperatures between 5 to 45 °C. The heat flux curves and heat transfer coefficients are also provided to a benchmark data for the actual impinging jet cooling applications of hot steel plate.
机译:水撞击喷射已广泛用于各种工程应用;特别是在热金属中的炼钢过程中的热钢冷却和热处理。冷却水温对撞击喷射冷却的影响主要研究了本研究的热钢板冷却。热通量通过新的实验技术测量,该实验技术具有高温热通量计的功能,其中使用测试块组件来测量热表面上的热通量分布。通过直管喷嘴制造的水撞击射流,并在固定水流速和固定喷嘴到靶间距下进行实验。结果表明,水温对撞击喷射传递特性的影响呈现在5至45℃之间的五种不同的水温。热通量曲线和传热系数也被提供给热钢板的实际撞击喷射冷却应用的基准数据。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号