首页> 外文会议>ASME/JSME thermal engineering joint conference;AJTEC2011 >EFFECT OF COOLING WATER TEMPERATURE ON IMPINGING JET HEAT TRANSFER ON HOT STEEL PLATE
【24h】

EFFECT OF COOLING WATER TEMPERATURE ON IMPINGING JET HEAT TRANSFER ON HOT STEEL PLATE

机译:冷却水温度对热钢板撞击射流传热的影响

获取原文

摘要

Water impinging jet has been widely used in a variety of engineering applications; especially in the hot steel cooling of steelmaking processes and heat treatment in hot metals. The effects of cooling water temperature on water impinging jet cooling are mainly investigated for hot steel plate cooling in this study. The heat flux are measured by a novel experimental technique that has a function of high-temperature heat flux gauge in which test block assemblies are used to measure the heat flux distributions on the hot surface. The water impinging jet is produced by a straight pipe nozzle and experiments are performed at fixed water flow rate and fixed nozzle-to-target spacing. The results show that effects of water temperature on impinging jet transfer characteristics are presented for five different water temperatures between 5 to 45 °C. The heat flux curves and heat transfer coefficients are also provided to a benchmark data for the actual impinging jet cooling applications of hot steel plate.
机译:喷水射流已广泛用于各种工程应用中。特别是在炼钢工艺的热钢冷却和高铁金属的热处理中。在本研究中,主要研究冷却水温度对水喷射射流冷却的影响。通过具有高温热通量计功能的新型实验技术来测量热通量,其中使用测试块组件来测量热表面上的热通量分布。喷水射流由直管喷嘴产生,并在固定的水流量和固定的喷嘴到目标间距的条件下进行实验。结果表明,在5至45°C的五种不同水温下,水温对撞击射流传递特性的影响得到了体现。热通量曲线和传热系数也被提供给基准数据,用于热钢板的实际冲击射流冷却应用。