The materials specifier is in need of test methods for acceptance and qualification testing to ensure that the supplied material exhibit desired properties. In the case of duplex stainless steels the ASTM A923 standard is used extensively as a qualification test for duplex grades UNS S32205 and S31803, and superduplex UNS S32750, to detect presence of detrimental intermetallic phases in base material or weldments. In the case of lean duplex stainless steel, ASTM A923 is unsuitable since the lean duplex grades, such as UNS S32101 and S32304, show a very different behavior if they are subjected to inappropriate heat treatment, compared to UNS S32205 and S32750.Recent developments towards creating a new version of ASTM A923 for lean duplex grades have resulted in a standard proposal where the corrosion testing is based on an inhibited ferric chloride solution, 5% FeCI_3 + 1% NaNO_3 which has been accepted as a standard, ASTM A1084. However, the new standard does not state criteria for welded conditions. The purpose of this work is to investigate the applicability of this inhibited solution on welded lean duplex stainless steel. Lean duplex grade UNSS32101 which has been flux cored arc welded with different filler metals according to recommended welding procedures, will be tested and evaluated according to the new standard.All the welded specimens tested in this study pass the corrosion test acceptance criteria for base metal given in ASTM A1084 Method C. All samples showed a corrosion rate lower than 10 mdd at 25°C, regardless of filler metal with proper post weld cleaning, while the weld metal showed lower values than the acceptance criteria given for the impact toughness for the base material at 70 J at room temperature. Impact toughness depends to a large extent on welding method, welding parameters, filler metal used and weld metallurgy.
机译:材料说明符需要用于接受和鉴定测试的测试方法,以确保提供的材料表现出所需的性质。在双相不锈钢钢的情况下,ASTM A923标准被广泛用于双面等级UNS S32205和S31803和SuperDuplex Unt S32750的验证测试,以检测基材或焊接中有害的金属间相的存在。在瘦双相不锈钢的情况下,由于瘦双相等级,例如UNS S32101和S32304,因此,如果未恰当的热处理,则ASTM A923是不合适的,因为没有S32205和S32750,如果对其进行不适当的热处理,则显示出非常不同的行为。为贫双工等级创建新版本的ASTM A923导致了标准提案,其中腐蚀检测基于抑制的氯化铁溶液,5%Feci_3 + 1%NaNO_3,其被认为是标准的ASTM A1084。但是,新标准不陈述焊接条件的标准。这项工作的目的是研究这种抑制溶液对焊接瘦双相不锈钢的适用性。根据推荐的焊接程序,使用不同的填充金属焊接的贫芯级UNS32101将根据推荐的焊接程序进行焊接,并根据新标准进行测试和评估。本研究中测试的焊接试样通过给定的基础金属的腐蚀测试验收标准在ASTM A1084方法C.所有样品在25°C下显示出低于10 mdd的腐蚀速率,无论填充金属有适当的焊接清洁,焊接金属显示出低于底座冲击韧性的验收标准的值较低的值70 j时的材料在室温下。冲击韧性在很大程度上取决于焊接方法,焊接参数,使用的填充金属和焊接金属冶金。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号