首页> 外文会议>Conference on Environmental Science and Information Application Technology >Determination of Trace Sodium in Water from High-Parameter Power Plant with Fluorescent Spectrometry
【24h】

Determination of Trace Sodium in Water from High-Parameter Power Plant with Fluorescent Spectrometry

机译:用荧光光谱法测定水中高参数发电厂水中痕量钠

获取原文

摘要

The fluorescent spectrometry used for trace amount of sodium determination with high sensitivity has been discussed in this paper, which was based on complexation of ortho-methoxyl tetraphenylporphyrin (o-OCH3TPP) and sodium ion with the excitation wavelength of 242nm. With the concentration of sodium ion increased, the fluorescence intensity of the complex increased at the emission wavelength of 655nm. The optimal buffer of Na-o-OCH_3TPP complex was selected as 10mM Tris-HCl solution, pH=8.87. The relative fluorescence intensity was proportional to the logarithmic value of concentration of Na~+ in the range of 1.00×10~(-9) to 1.00×10~(-3)mol/L, while the concentration of o-CH_3TPP was 1.269×10~(-5)mol/L, the corresponding correlation coefficient was 0.9804 (n=7), the detection limit can be estimated to about 3.00×10~(-10)lmol/L. No significant interferences were observed from alkali metals and alkaline metals, like K~+, Ca~(2+), Mg~(2+), and Li~+. In addition, the proposed method possessed a very nice reproducibility and stability. With standard addition method, the presented method possessed a nice recovery rate of 96.3-104.5% for detection of sodium in water samples from a thermal power plant, indicating that the method can be well used for the determination of trace sodium ion in water in high-parameter power plants.
机译:用于测定钠具有高灵敏度微量荧光光谱法已在本文中,这是基于邻 - 甲氧基四苯基卟啉(邻OCH3TPP)和钠与242nm的激发波长离子络合已讨论过。随着钠离子的浓度增加,复合物的荧光强度在散发波长为655nm时增加。将Na-O-Och_3TPP复合物的最佳缓冲液选择为10mm Tris-HCl溶液,pH = 8.87。相对荧光强度与Na〜+的浓度的对数值成比例,其范围为1.00×10〜(-9)至1.00×10〜(-3)Mol / L,而O-CH_3TPP的浓度为1.269 ×10〜(-5)mol / l,相应的相关系数为0.9804(n = 7),检测极限可以估计为约3.00×10〜(-10)Lmol / L.从碱金属和碱金属中没有观察到显着的干扰,如K〜+,Ca〜(2+),Mg〜(2+)和Li〜+。此外,所提出的方法具有非常好的再现性和稳定性。采用标准加法方法,呈现的方法具有96.3-104.5%的良好回收率,用于检测来自火电厂的水样中的钠,表明该方法可以很好地测定水中的痕量钠离子 - 参数电厂。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号